Allen-Bradley Kinetix 5700 iTRAK Installation Instructions Manual page 14

Power supply and bus conditioner module
Table of Contents

Advertisement

Kinetix 5700 iTRAK Power Supply and iTRAK Bus Conditioner Module
Wire the iTRAK PS Ready (IR) Connector
The iTRAK PS relay output is part of a required I/O interface with the gateway and is connected to the gateway through the digital USB I/O
module.
iTRAK PS Ready (IR) Connector Wiring - Connector Plug
iTRAK PS Ready (IR) Connector Plug
-
+
Table 1 - iTRAK PS Ready (IR) Connector Plug Specifications
Description
Pin
Signal
2
-
iTRAK power supply
ready
1
+
see
Connect an iTRAK Power Supply to a System on page 21
14
2198T-W25-ER
iTRAK Power Supply
(front view)
MOD
NET
2
1
I/O
1
6
iPS RDY
5
10
Recommended Wire Size
Strip Length
mm2 (AWG)
mm (in.)
0.14...2.5
7.0 (0.28)
(26...12)
for wire diagram information.
Rockwell Automation Publication 2198T-IN001C-EN-P - October 2019
Torque Value
N•m (lb•in)
0.4...0.5
(3.5...4.4)

Advertisement