Allen-Bradley Kinetix 5700 iTRAK Installation Instructions Manual page 10

Power supply and bus conditioner module
Table of Contents

Advertisement

Kinetix 5700 iTRAK Power Supply and iTRAK Bus Conditioner Module
iTRAK Power Supply Connectors
Designator
Description
DC
DC common bus power
CP
24V control input power
IDC
iTRAK DC bus output A and B
ICP
iTRAK 24V control output power A and B
IOD
Digital inputs
IR
iTRAK power supply ready
PORT1, PORT2
Ethernet communication ports
DC Bus Input Power Connector
DC Pin
Description
Bus bar
DC bus connections
Control Input Power (CP) and Control Output Power A and B (ICP) Connectors Pinout
Pin
Description
2
24V common
1
24V power supply, customer-supplied
iTRAK Power Supply Ready (IR) Connector Pinout
IR Pin
Description
2
iTRAK power supply ready
1
DC Power Bus Output A and B (IDC) Connectors Pinout
IDC Pin
Description
4
Chassis ground
3
DC high voltage
2
DC low voltage
1
DC-bus
Digital Inputs (IOD) Connector Pinout
IOD Pin
Description
1
Digital input #1
2
I/O common for customer-supplied 24V supply
3
Digital input #2
4
I/O common for customer-supplied 24V supply
5
I/O cable shield termination point
6
Digital input #3
10
Connector
DC-bus links and end caps
2-position plug, terminal screws
4-position plug, terminal screws
2-position plug, terminal screws
10-position plug, spring terminals
2-position plug, terminal screws
RJ45 Ethernet
Signal
DC–
DC+
Signal
24V-
24V+
Signal
RDY-
RDY+
Signal
GND
H
L
DC-
Signal
Enable
COM
Fault Clear
COM
SHLD
IN3
Rockwell Automation Publication 2198T-IN001C-EN-P - October 2019
Control Input Power (CP) Connector
Control Output Power A and B (ICP) Connectors
-
+
1
6
7
2
3
8
4
9
5
10

Advertisement

Table of Contents
loading

Table of Contents