Kinetix 5700 iTRAK Power Supply and iTRAK Bus Conditioner Module
7. To hold the wires together, bundle the group of four wires with the previously trimmed filler material and slip on a 45 mm (1.8 in.) length
piece of shrink tube.
8. Slide previously trimmed piece of the outer braided shield over the entire bundle, butt it up to the cable jacket, pull tight, then trim the piece
so it is approximately 75 mm (2.9 in.) long.
9. Place a 64 mm (2.5 in.) length of adhesive-lined shrink tube over the cable located 113 mm (4.4 in.) from the end of the wires.
10. Place a 23 mm (0.9 in.) length piece of adhesive-lined shrink tube over the cable so that a 35 mm (length of shielded braid is left exposed.
64 mm
(2.5 in.)
11. Trim the braided shield on the twisted-pair shield back 40 mm (1.6 in.) from the end of the wires.
12. Place a 20 mm (0.79 in.) length piece of shrink tube over the twisted pair approximately 30 mm (1.18 in.) from the end of the wires.
16
Bundle wires with the previously
trimmed filler material into a diameter
approximately 8 mm (0.32 in.) and cover
with heat shrink.
75 mm
(3 in.)
75 mm
(3 in.)
Slide expanded tubular braids over all
conductors butt up to cable jacket and
pull tight.
75 mm
(3 in.)
23 mm
35 mm
(1.4 in.)
(0.9 in.)
Adhesive lined heat shrink two places.
Jacket
Rockwell Automation Publication 2198T-IN001C-EN-P - October 2019
Dimensions are in mm (in.)
Dimensions are in mm (in.)
138 mm
Dimensions are in mm (in.)
(5.4 in.)