Allen-Bradley Kinetix 5700 iTRAK Installation Instructions Manual page 20

Power supply and bus conditioner module
Table of Contents

Advertisement

Kinetix 5700 iTRAK Power Supply and iTRAK Bus Conditioner Module
3. Orient the bus conditioner module on over the four mounting holes in the iTRAK spine bar as shown.
4. Apply Loctite 222 to the four M6 x1, 30 mm screws.
5. Insert the four screws and torque them to 2.5...3 N•m (1.8...2.2 lb•ft)
6. Replace the bus conditioner module cover by routing the ground wire as shown while installing the cover.
IMPORTANT
The cover must be oriented correctly for proper installation. Incorrect installation causes an improper environmental seal. To aid in correct
orientation, the cover does not lie flush when incorrectly placed.
7. Torque the four screws to 2.5...3 N•m (1.8...2.2 lb•ft).
The ground wire that connects to
the cover of the enclosure is routed
around on the perimeter of the
enclosure and the capacitors.
8. Route and connect the bus conditioner module cable to the iTRAK motor module by using the example that is shown.
20
M6 x1, 30 mm long mounting
screws (X4)
Pre-drilled and tapped mounting
holes in the spine bar (X4).
Alignment standoff that is on the side
opposite of the connector and it fits
between the capacitors.
Rockwell Automation Publication 2198T-IN001C-EN-P - October 2019