[Commands] Menu
Maintenance - Help(?)
This command is used to show the help messages of [Remote Commands].
Conditions:
Procedure:
Diagnostic - Configuration Constraint(db cc)
Shows if the current configuration meets the configuration constraints.
Diagnostic - Preprogrammed Fault(db pf)
Shows preprogrammed faults. Checks if the admin programmed data are different from the
boards that are installed in the system. Prints a warning message if there is any difference.
Diagnostic - Time-slot Conflict(db ts [sl][cf])
Shows time-slot assignment table and time-slot assignment conflict status. In case of PRIB,
channel 31, 32 should be assigned the same time slot with that of channel 1. Command options
are:
[sl] - time-slot assignment table
[cf] - time-slot conflict
Diagnostic - Hiway Test(db ht ## ## #)
Tests PCM hiways using one DKT and one DTMF receiver. If you assign slot number, dtmf
receiver duration time, and hiway number, this program tests 48 time-slots in the specified
hiway. Note that the first DKT of the assigned slot is used for the test. The DKT is connected to
time-slot successively and DTMF tone is connected to that time-slot too. If the DKT receives
the specified DTMF tone, we consider the time-slot is operating correctly.
Usage: db ht xx yy # ( xx: slot number (DTIB), yy: dtmf duration time, #: hiway number(0-7))
This command can be executed when this program is connected to the SBX IP 320
system.
Select the [Help Message] sub-menu in the [Commands] menu, or click the [Help
Message] [Command Bar] button.
-or-
Input "?" in the [SBX IP 320 Command Edit Box] and then click the [Enter] button, or
select [Help Message] in the [Remote Command Combo Box] and then click the
[Execute] button.
SBX IP 320 Installation Guide
Chapter 9: Remote Diagnostics
-
9
35