1. Ensure that the Silicon Labs VCP USB-UART drivers are installed Silicon Labs CP210x USB-to-
UART Installation Guide (UG1033).
2. Download the board user interface Host PC application from the board documentation web
page.
3. Connect the micro-USB cable to ZCU216 USB-UART connector (J24).
4. Power-cycle the ZCU216.
5. Observe that SYSCTLR LED0 (DS9) blinks and LED1 (DS10) is illuminated.
6. Launch the board user interface application.
On first use of the board user interface, go to the FMC → Set VADJ → Boot-up tab and click USE
FMC EEPROM Voltage. The board user interface buttons grey-out during command execution
and return to their original appearance when ready to accept a new command.
See the ZCU216 System Controller GUI Tutorial (XTP_TBD) and the ZCU216 Software Install and
Board Setup Tutorial (XTP_TBD) for more information on installing and using the System
Controller board user interface utility.
Switches
[Figure
2, callouts 23 and 24]
The ZCU216 board includes the following power, configuration, and reset switches:
• SW15 Power On/Off slide switch (callout 24)
• SW3 (PS_PROG_B), active-Low pushbutton (callout 23)