The detailed RFSoC connections for the feature described in this section are documented in the
ZCU216 board XDC file, referenced in
The following table lists the zSFP+ module control and status connections.
Table 19: zSFP Control and Status Board Connections
zSFP Control/ Status Signal
1,
2
SFP0 J29 LT
SFP_TX_FAULT
SFP_TX_DISABLE
SFP_MOD_DETECT
SFP_RS0
SFP_RS1
SFP_LOS
1,
2
SFP1 J29 LL
SFP_TX_FAULT
SFP_TX_DISABLE
SFP_MOD_DETECT
UG1390 (v1.1) July 10, 2020
ZCU216 Board User Guide
Figure 16: Quad-zSFP Connector zSFP Locations
Appendix B: Xilinx Design
Test Point TP11
Jumper J39
Switch Q6 U1.K16
Test Point J12
PU R262 / PD R269
PU R263 / PD R264
Test Point TP13
Test Point TP14
Jumper J44
Switch Q7 U1.K17
Test Point TP15
Chapter 3: Board Component Descriptions
Constraints.
Board Connection
High = Fault
Low = Normal Operation
Off = SFP Disabled
On = SFP Enabled
High = Module not present
Low = Module Present
PU R262 = Full RX bandwidth
PD R269 = Reduced RX bandwidth
PU R263 = Full TX bandwidth
PD R264 = Reduced TX bandwidth
High = Loss of receiver signal
Low = Normal operation
High = Fault
Low = Normal Operation
Off = SFP Disabled
On = SFP Enabled
High = Module not present
Low = Module Present