Access Options - HPE ProLiant e910 User And Maintenance Manual

Table of Contents

Advertisement

Access options

You can configure the following settings in the Access Options section on the Access Settings page.
Idle Connection Timeout (minutes)
Specifies how long an iLO session can be inactive before it ends automatically.
The iLO web interface and the Remote Console track idle time separately because each connection is a separate session.
This setting has no effect on a Remote Console session if a Virtual Media device is connected.
The following values are valid:
15, 30, 60, or 120 minutes—The default value is 30 minutes.
Infinite—Inactive users are not logged out.
Failure to log out of iLO by browsing to a different site or closing the browser window results in an idle connection. The
iLO firmware supports a finite number of connections. Misuse of the Infinite timeout option might make iLO inaccessible
to other users. Idle connections are recycled after they expire.
This setting applies to local and directory users. Directory server timeout settings might pre-empt the iLO setting.
Changes to the setting might not take effect immediately in current user sessions, but will be enforced immediately in all
new sessions.
iLO Functionality
Specifies whether iLO functionality is available.
When this setting is enabled (default), the iLO network is available and communications with operating system drivers are
active.
When this setting is disabled, the iLO network and communications with operating system drivers are terminated.
To re-enable iLO functionality, use the UEFI System Utilities. For more information, see the UEFI System Utilities user
guide.
iLO functionality cannot be disabled on ProLiant server blades or Synergy compute modules.
iLO Web Interface
Specifies whether the iLO web interface can be used to communicate with iLO. This setting is enabled by default.
iLO RIBCL Interface
Specifies whether RIBCL commands can be used to communicate with iLO. This setting is enabled by default.
RIBCL over HTTP/HTTPS, RIBCL through in-band communication, and RIBCL through the OA port do not work when this
feature is disabled.
This option must be enabled when you register a server for Insight Remote Support central connect or Remote Support
from HPE OneView.
The following message is displayed if you try to use RIBCL when it is disabled:
<?xml version="1.0"?>
<RIBCL VERSION="2.23">
<RESPONSE
STATUS="0x00FC"
MESSAGE='RIBCL is disabled.'
/>
</RIBCL>
iLO ROM-Based Setup Utility
Enables or disables the iLO configuration options in the UEFI System Utilities.