Omni 4000 Series Installation Manual page 95

Flow computer
Hide thumbs Also See for 4000 Series:
Table of Contents

Advertisement

3.
In the Setup Sites window, click Add Site
to open the Setup Communications
window.
4.
a. In the Setup Communications
window, select Serial Port from the
Media Type drop-down list.
b. In the Site Name field, enter a
name for this site.
c. Select the the serial port number
on your PC from the Comm Port
drop-down list. This number is not the
flow computer serial port number.
d. Adjust all the other parameters to
match the values specified when the
serial port was configured from the
front panel of the flow computer.
5.
Click Add Unit to open the Setup Unit
window.
In the Setup Unit window, enter a name
6.
for your flow computer in the Unit Name
field.
Make sure that the other parameters
match the serial port settings in the flow
computer (go to Section 4.3.1 if needed).
Click OK to save the changes.
7.
Repeat Steps 5 and 6 to add more units
to this serial port site, as needed.
4-35
OMNI 4000/7000 Installation Guide – Rev H
Configuration