Omni 4000 Series Installation Manual page 130

Flow computer
Hide thumbs Also See for 4000 Series:
Table of Contents

Advertisement

4.
If the flow computer is equipped with a
gas chromatograph (selected on the
Equipment List screen in Section 4.10.1),
select Gas Chromatograph on the tree
(Gas Chromatograph is available with
Firmware version 2.11 and higher for the
US Liquid K-Factor Linearization
Application. It requires the purchase of an
Advanced firmware license with the API
MPMS CH. 14.7/14.4 feature enabled.).
5.
a. Fill in the required information.
b. When you are finished, click
Apply to save the changes.
Press F1 to access
OMNICONNECT Help for
assistance.
Gas
To configure gas fluid products if the flow computer is configured for gas applications, follow
these instructions:
Select Fluid Products in the Configure
1.
tree in the left panel and expand the list to
see the entire list of products.
For gas applications, there are six
default products. You do not have
to use or configure all of them.
2.
a. Select a product in the tree to
display its configuration options in the
screens on the right.
b. Fill in the information in the
screens for both tabs, as needed.
c. When you are finished, click Apply
to save the changes.
Press F1 to access
OMNICONNECT Help for
assistance.
4-70
OMNI 4000/7000 Installation Guide – Rev H