Environmental
Operating Temperature
Storage Temperature
Relative Humidity
Mechanical
Electrical
Electrical
Supply Voltage for Power Supply
Module Model 68-6218
Transducer Output Power
Isolation
Power Fuse
Transient/Over-voltage Protection
for Power Supply Module
Model 68-6218
Page 8-2
OMNI 4000/7000 Installation Guide – Rev H
Operating Parameters
+14 °F to +140 °F (-10 °C to +60 °C)
-4 °F to +158 °F (-20 °C to +70 °C)
90% non-condensing maximum
Class M3 (high levels of vibration) as defined in
OIML R117-1:2007
Class E2 (heavy industrial environments) as defined in
OIML R117-1:2007
Specifications
90 to 264 VAC, 47 to 440 Hz or 22 to 26 VDC
10 to 22 W (excluding transducer loops)
10 to 35 W (including transducer loops)
Caution: Maximum DC offset from +DC or -DC to Earth
Ground is 120 VDC.
24 VDC at approximately 350 mA for most
configurations
(when AC powered)
All analog inputs and outputs are electrically isolated
from computer logic supply.
Maximum common mode voltage on any input or
output is ±250 VDC to chassis ground.
Located on Standard/Extended Back Panels
Standard Back Panel (4000/7000)
DC Fuse 5x20 = 3.15 A Slow Blow
(Littelfuse #02183.15)
AC Fuse 5x20 = 1.6 A Fast Blow
(Littelfuse #021701.6)
Extended Back Panel (7000)
DC Fuse 2AG = 3 A Slow Blow
(Littelfuse #0229003)
DC Fuse for Transducer Loop power
2AG = 250 mA Fast Blow (Littelfuse #0225.250)
AC Fuse 5x20 = 1.6 A Fast Blow
(Littelfuse #021701.6)
Current limiting circuit and Transzorbs