Omni 4000 Series Installation Manual page 162

Flow computer
Hide thumbs Also See for 4000 Series:
Table of Contents

Advertisement

Abnormal
The display is showing
No display
system data and menus
No key press beeps
Keypress functions for screen
navigation includes a beep
with each key press
Abnormal
Battery voltage LED
Battery voltage indicator
indicator illuminated red
illuminated green
Page 7-3
OMNI 4000/7000 Installation Guide – Rev H
Front Panel
Normal
Possible Causes
Power source malfunction
An overcurrent condition overloaded a
fuse, tripping it
A front panel ribbon cable malfunction
Front panel is faulty
CPU
Normal
Possible Causes
Power not applied
LED burned out
Coin cell battery needs replace
Troubleshooting
Suggested Action
Check the heartbeat.
Check that the front panel keys
beep when pressed.
Check the system power.
Use OMNIPANEL to verify the flow
computer is functioning properly.
If there is normal front panel
functionality through OMNIPANEL,
check the front panel ribbon cable:
Inspect for damage to cable and
no bent pins.
Verify the cable is installed with
the correct orientation
Replace the front panel with a spare
to test.
Suggested Action
Verify that the flow computer is
powered on.
Test the front panel. If there is a
response, the LED is burned out.
Replace the CPU card (optional).
Replace the cell battery