OMNI 4000/7000 Installation Guide – Rev H
On the Setup screen, if you choose Select Mass Pulses the Viscosity
Linearization tab is deactivated and the Reynolds Correction and Reynolds MF
Curve tabs become available to use. These configurations are optional for certain
types of Coriolis meters.
On the Reynolds Correction tab, select the Use Reynolds Correction check box if
the correction is required for your meter. The supported meter model numbers are
listed in the Meter Model drop-down box.
The Reynolds MF Curve tab has the entry fields for the Meter Factors, Reynolds
Numbers, and Flow Rates for each curve data point. The Flow Rate settings are for
informational purposes only and are not used in the calculations.
For detailed information on configuring the Reynolds correction for a meter, refer to
OMNICONNECT Help.
4-65
Configuration