Pinouts
Signal Name
Signal Return Terminals 9,
10
11 and 12
Analog Output #1
11
RTD Excitation Current
12
Source #2
E/D Module
Input Channel #1
1
Input Channel #1
2
Input Channel #2
3
Input Channel #2
4
Input Channel #3
5
Input Channel #4
6
7
RTD Excitation Current
8
Source #2
RTD Excitation Current
9
Source #1
Signal Return for Terminals
10
5, 6, 8, 9, 11 and 12
Analog Output #1
11
Analog Output #2
12
E Module
Input Channel #1
1
Input Channel #1
2
Input Channel #2
3
Input Channel #2
4
Input Channel #3
5
Input Channel #4
6
Double Chronometry
7
Detector Switch Input
3-31
OMNI 4000/7000 Installation Guide – Rev H
Signal Type
Internally Connected to DC Power Return
4-20 mA
3.45 mA Current Source
1-5 V, 4-20 mA or RTD
Isolated Signal Return
1-5 V, 4-20 mA or RTD
Isolated Signal Return
AC or DC Coupled Digital Densitometer Pulses
AC or DC Coupled Digital Densitometer Pulses
— NOT USED —
3.45 mA Current Source
3.45 mA Current Source
Internally Connected to DC Power Return
4-20 mA
4-20 mA
1-5 V, 4-20 mA or RTD
Isolated Signal Return
1-5 V, 4-20 mA or RTD
Isolated Signal Return
AC or DC Coupled Flowmeter Pulses
AC or DC Coupled Flowmeter Pulses
Active Low