5.5

Manual mode, general

The following can be carried out in the manual mode:
Wastewater pump ON / OFF
Move the backwater flap to the OPEN / CLOSED position
5.5.1

Wastewater pump manual mode

1. Activate manual operation
Press the Pump key  <26>, the pump LED <23> flashes, the wastewater
pump will now no longer be switched on automatically. If manual
operation is activated during pumping-off, the wastewater pump is
switched off.
2. Switch on wastewater pump
The wastewater pump can be switched on as follows when manual
operation is activated:
Switching on briefly
Switching on for longer
The manual mode is switched off automatically after the wastewater pump has been switched on. If manual
operation is not used for a certain period of time, the control unit re-activates the automatic mode.
5.5.2

Backwater flap manual mode

Closing the backwater flap in the manual mode
Only possible if there is no backwater present. The backwater flap
LED <22> must be off and „Backwater: no" must be shown on the
display.
Press the backwater flap key  <25>, the backwater flap is moved from
the OPEN to the CLOSED position. The backwater flap LED <22> flashes
during the change of position. The backwater
flap is closed when the backwater flap LED <22> comes one, the display
also shows "Flap closed".
2019/04
Press the pump key <26> 1x , the
wastewater pump is switched on for a
short time.
Press and hold down the pump key <26>
for as long as the wastewater pump is to
be switched on.
47 / 168
26
23
FLAP
PUMP
Fig. [19]
25
22
FLAP
PUMP
Fig. [20]