3.

Installation

3.1.

Installing the control unit

• Disconnect from the mains <41> and open the housing,
to do this loosen the two screws <34> (turn anticlockwise)
and open the housing cover.
• Note: Use the drilling template/included.
• Mount the housing in the designated spot, using both
attachment possibilities to do this. A drilling template
is included in the scope of delivery.
• Close the housing cover and tighten both screws
<34> (turn clockwise).
3.2.

Connecting the wastewater pump(s)

Connect the wastewater pump(s), to do this connect
the cable plug for the pump <40> as shown in Fig. [7].
Tighten the nut using 3 Nm. The gap <35> between
nut and plug-type connection is then 3-4 mm
(See Fig. [8])
The pump cable can be lengthened or shortened.
Refer to section 5.1 Shortening or lengthening the
pump/probe connection cable