Parameters
12-94 Broadcast Storm Protection
Range:
-1 %
[-1 -
20 %]
*
5
5
12-95 Inactivity timeout
Range:
120
*
12-96 Port Config
Enable/disable port-mirroring function. For troubleshooting with
a network analyzer tool.
Option:
[0]
Normal
[1]
Mirror Port 1 to 2
[2]
Mirror Port 2 to 1
[10]
Port 1 disabled
[11]
Port 2 disabled
[254]
Mirror Int. Port to 1
[255]
Mirror Int. Port to 2
12-98 Interface Counters
Range:
4000
[0 - 4294967295] Read-only. Advanced interface
*
12-99 Media Counters
Range:
0
[0 - 4294967295] Read-only. Advanced interface counters
*
30
Function:
The built-in switch is capable of protecting the
switch system from receiving too many broadcast
packages, which can use up network resources. The
value indicates the percentage of the total
bandwidth that is allowed for broadcast messages.
Example:
OFF means that the filter is disabled: All broadcast
messages pass through. The value 0% means that
no broadcast messages pass through. A value of
10% means that 10% of the total bandwidth is
allowed for broadcast messages. If the number of
broadcast messages increases above the 10%
threshold, they are blocked.
Function:
[0 - 3600]
Function:
No port-mirroring.
All network traffic on port 1 is
mirrored to port 2.
All network traffic on port 2 is
mirrored to port 1.
Function:
counters from the built-in switch can
be used for low-level troubleshooting.
The parameter shows a sum of port
1+port 2.
Function:
from the built-in switch can be used for
low-level troubleshooting. The parameter
shows a sum of port 1+port 2.