Parameters
Parameter
Parameter 8-58 Profidrive OFF3
Select
Parameter 8-79 Protocol Firmware
version
Parameter 8-80 Bus Message Count
Parameter 8-81 Bus Error Count
Parameter 8-82 Slave Messages
Rcvd
Parameter 8-83 Slave Error Count
5
5
Parameter 8-84 Slave Messages Sent
Parameter 8-85 Slave Timeout Errors
Parameter 8-88 Reset FC port
Diagnostics
Parameter 8-90 Bus Jog 1 Speed
Parameter 8-91 Bus Jog 2 Speed
Parameter 12-00 IP Address
Assignment
Parameter 12-01 IP Address
Parameter 12-02 Subnet Mask
Parameter 12-03 Default Gateway
Parameter 12-04 DHCP Server
Parameter 12-05 Lease Expires
Parameter 12-06 Name Servers
Parameter 12-07 Domain Name
Parameter 12-08 Host Name
Parameter 12-09 Physical Address
Parameter 12-10 Link Status
Parameter 12-11 Link Duration
Parameter 12-12 Auto Negotiation
Parameter 12-13 Link Speed
Parameter 12-14 Link Duplex
Parameter 12-18 Supervisor MAC
Parameter 12-19 Supervisor IP Addr.
Parameter 12-20 Control Instance
Parameter 12-21 Process Data
Config Write
Parameter 12-22 Process Data
Config Read
Parameter 12-28 Store Data Values
Parameter 12-29 Store Always
Parameter 12-30 Warning
Parameter
Parameter 12-31 Net Reference
Parameter 12-32 Net Control
Parameter 12-33 CIP Revision
Parameter 12-34 CIP Product Code
Parameter 12-35 EDS Parameter
Parameter 12-37 COS Inhibit Timer
Parameter 12-38 COS Filter
Parameter 12-80 FTP Server
Parameter 12-81 HTTP Server
Parameter 12-82 SMTP Service
32
EtherNet/IP
Default value
4 set-up
[3] Logic OR
All set-ups
1 set-up
0
1 set-up
0
1 set-up
0
1 set-up
0
1 set-up
0
1 set-up
0
1 set-up
[0] Do not reset
1 set-up
100 RPM
All set-ups
200 RPM
All set-ups
[10] DCP
1 set-up
0
1 set-up
0
1 set-up
0
1 set-up
0
1 set-up
All set-ups
0
1 set-up
0
1 set-up
0
1 set-up
0
1 set-up
[0] No Link
All set-ups
All set-ups
[1] On
1 set-up
[0] None
1 set-up
[1] Full Duplex
1 set-up
0
2 set-ups
0
2 set-ups
1 set-up
[0] None
All set-ups
[0] None
All set-ups
[0] Off
All set-ups
[0] Off
1 set-up
0
All set-ups
[0] Off
All set-ups
[0] Off
All set-ups
All set-ups
1 set-up
0
All set-ups
0
All set-ups
0
All set-ups
[0] Disabled
1 set-up
[0] Disabled
1 set-up
[0] Disabled
1 set-up
Danfoss A/S © 06/2016 All rights reserved.
Change during
Conversion
operation
index
TRUE
FALSE
-2
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
TRUE
0
TRUE
0
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
0
TRUE
0
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
0
TRUE
TRUE
TRUE
TRUE
TRUE
0
TRUE
0
TRUE
0
TRUE
TRUE
TRUE
Type
Uint8
Uint16
Uint32
Uint32
Uint32
Uint32
Uint32
Uint32
Uint8
Uint16
Uint16
Uint8
Oct. string 4
Oct. string 4
Oct. string 4
Oct. string 4
Time diff. w/date
Oct. string 4
Visible string 48
Visible string 48
Visible string 17
Uint8
Time diff. w/date
Uint8
Uint8
Uint8
Oct. string 6
Oct. string 4
Uint8
Uint16
Uint16
Uint8
Uint8
Uint16
Uint8
Uint8
Uint16
Uint16
Uint32
Uint16
Uint16
Uint8
Uint8
Uint8
MG07H102

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents