Danfoss EtherNet/IP Midi Drive FC 280 Programming Manual page 31

Hide thumbs Also See for EtherNet/IP Midi Drive FC 280:
Table of Contents

Advertisement

Parameters
12-37 COS Inhibit Timer
Range:
Function:
0
[0 -
Change-of-state inhibit timer. If the option is
*
65535]
configured for COS operation, this inhibit timer
can be configured in the forward open telegram
to prevent that continuously changing PCD data
generat extensive network traffic. The inhibit
time is in milliseconds, 0 = disabled.
12-38 COS Filter
Range:
Function:
0
[0 - 65535] Change-of-state PCD filters. Set up a filter mask
*
for each word of process data when operating
in COS-mode. Single bit in the PCD's can be
filtered in/out.
5.2.5 12-8* Other Ethernet Services
12-80 FTP Server
Option:
Function:
[0]
Disabled
Disable the built-in FTP server.
*
[1]
Enabled
Enable the built-in FTP server.
12-81 HTTP Server
Option:
Function:
[0]
Disabled
Disable the built-in HTTP (web) server.
*
[1]
Enabled
Enable the built-in HTTP (web) server.
12-82 SMTP Service
Option:
Function:
[0]
Disabled Disable the SMTP (e-mail) service on the option.
*
[1]
Enabled
Enable the SMTP (e-mail) service on the option.
12-83 SNMP Agent
Option:
Function:
[0]
Disabled
Disable the local SNMP agent.
[1]
Enabled
Enable the local SNMP agent.
*
12-84 Address Conflict Detection
Option:
Function:
[0]
Disabled Disable the function which detects and resolves
IP address conflicts with this device in the
network.
[1]
Enabled Enable the function which detects and resolves IP
*
address conflicts with this device in the network.
12-89 Transparent Socket Channel Port
Range:
Function:
4000
[0 - 65535] Configure the TCP port number for the
*
transparent socket channel. This configu-
ration enables FC telegrams to be sent
transparently on Ethernet via TCP. Default
MG07H102
Programming Guide
12-89 Transparent Socket Channel Port
Range:
5.2.6 12-9* Advanced Ethernet Settings
12-90 Cable Diagnostic
Option:
[0]
Disabled Disable the cable diagnostic function.
*
[1]
Enabled Enable the cable diagnostic function.
12-91 Auto Cross Over
Option:
[0]
Disabled
[1]
Enabled
*
12-92 IGMP Snooping
Option:
[0]
Disabled Disable the IGMP snooping function.
[1]
Enabled Enable the IGMP snooping function.
*
12-93 Cable Error Length
Range:
0
[0 -
*
65535]
Danfoss A/S © 06/2016 All rights reserved.
Function:
value is 4000, 0 means disabled. The uses
this port.
Function:
NOTICE
The cable diagnostics function is only
issued on ports where there is no link (see
parameter 12-10 Link Status, Link Status).
Enable/disable advanced cable diagnosis function.
If enabled, the distance to cable errors can be
read out in parameter 12-93 Cable Error Length.
The parameter resumes to the default setting of
disable after the diagnostics have finished.
Function:
Disable the auto-crossover function.
Enable the auto-crossover function.
Function:
This prevents flooding of the Ethernet protocol
stack by only forwarding multicast packets to
ports that are member of the multicast group. In
PROFINET, this function is disabled.
Function:
If cable diagnostics is enabled in
parameter 12-90 Cable Diagnostic, the built-in
switch is possible via time domain reflectometry
(TDR). This measurement technique detects
common cabling problems such as open circuits,
short circuits, and impedance mismatches or
breaks in transmission cables. The distance from
the option to the error is shown in meters with an
accuracy of ±2 m (6.56 ft). The value 0 means that
no errors are detected.
5