Siemens SINUMERIK 840D sl Function Manual page 913

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

2.4.12
Control system response
2.4.12.1
POWER ON
Frame conditions after POWER ON
Frame
Programmable frame
Settable frames
Complete basic frame
System frames
Zero offset external
DRF offset
2.4.12.2
Mode change
System frames
System frames are retained and remain active when the operating mode is changed.
JOG mode
In JOG mode, the frame components of the current frame are only taken into account for the
geometry axes if a rotation is active. No other axial frames are taken into account.
PLC and command axes
The response for PLC and command axes can be set via machine data:
MD32074 $MA_FRAME_OR_CORRPOS_NOTALLOWED (Frame or HL correction is not
permissible)
Basic logic functions: Axes, coordinate systems, frames (K2)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Frame conditions after POWER ON
Deleted.
Is retained, depending on:
MD20110 $MC_RESET_MODE_MASK
Retained, depending on
MD20110 $MC_RESET_MODE_MASK bit 0 and bit 14
Individual basic frames can be deleted with
MD10615 $MN_NCBFRAME_POWERON_MASK
and
MD24004 $MC_CHBFRAME_POWERON_MASK
.
Retained
Depending on:
MD24008 $MC_CHSFRAME_POWERON_MASK
, individual system frames can be deleted on POWER ON.
Deletion of system frame is executed in the data
management on first priority.
Permanent, but has to be activated again.
The system frame is retained.
Deleted.
Detailed description
2.4 Frames
129

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di slSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840d powerlineSinumerik 840de powerline ... Show all

Table of Contents