4.5 Notes on Using This Product (1)

Notes on using this product are listed below. Be sure to read these notes before using this product.
重 要要

Note on Downloading Firmware:

Do not shut off the power while downloading the firmware. If this happens, the product will not start up
properly. If power is shut off unexpectedly, redownload the firmware.

Notes on the Self-check:

If the self-check does not result normally, the emulator may be damaged. Then contact your local distributor.
Run the self-check with the user system not connected.

Note on Quitting the Emulator Debugger:

To restart the emulator debugger after it ends, always shut power to the emulator module off once and then on
again.

Notes on the User System (Power Supply, Order of Powering On):

When the user system is connected, be sure to set the JP1 of the control board (upper board) to "EXT".
This emulator cannot supply the power to the user system. Therefore design your system so that the user system
is powered separately.
This emulator consumes max. 500 mA of electric current from the user system.
The voltage of the user system should be as follows.
2.7 V ≤ Vcc ≤ 5.5 V
Do not change the voltage of the user system after turning on the power. When you change the voltage of the
user system, be sure to set the JP1 of the R0E436640EPBM0 to the "EXT POWER" side
Before powering on your emulator system, check that the host machine, the emulator, the converter board and
user system are all connected correctly. Next, turn on the power to each equipment following the procedure
below.
(1) Turn ON/OFF the user system and the emulator as simultaneously as possible.
(2) When the emulator debugger starts up, check the target status LEDs on the emulator to see if this product
is ready to operate.
Is the power supplied? Check that target status LED (POWER) is ON.*1
Is the Φ supplied?
*1 When the user system is not connected the target status LED (POWER) does not light. Note that the
target status LED (POWER) light when the JP1 of the R0E436640EPBM0 is set to the "EXT POWER"
side.
REJ10J0918-0300 Rev.3.00 February 15, 2007
IMPORTANT
Check that target status LED (CLOCK) is ON.
4 Hardware Specifications