en | System Configuration
Notice!
UL 864 requirement for commercial fire
To comply with UL864 requirements for commercial fire systems, set this parameter to
Enabled.
USB Menu Location
[4] System Configuration > [3] Battery Supervision > [1] Battery Monitoring
8.3.2

Battery faults send reports

Default: Enabled
Selections:
Notice!
UL 864 requirement for commercial fire
To comply with UL864 requirements for commercial fire systems, set this parameter to
Enabled.
USB Menu Location
[4] System Configuration > [3] Battery Supervision > [2] Battery faults send reports
8.3.3

Battery faults set Trouble Output

Default: Disabled
Selections:
USB Menu Location
[4] System Configuration > [3] Battery Supervision > [3] Battery faults set Trouble Output
8.4

Tamper

Use the parameters in this section to configure the B465 to monitor an enclosure tamper
switch.
8.4.1

Tamper sends reports

Default: Disabled
Selections:
When an enclosure tamper switch is connected to the B465 tamper circuit (TMPR connector),
opening the enclosure door is a fault.
USB Menu Location
[4] System Configuration > [4] Tamper > [1] Tamper sends reports
8.4.2

Tamper sets Trouble Output

Default: Disabled
Selections:
2017.11 | 05 | F.01U.311.207
Enabled - the B465 sends reports for low and missing battery faults.
Disabled - the B465 does not send reports for battery faults.
Enabled - when there is a battery fault, the B465 sets the trouble output.
Disabled - the B465 does not set the trouble output for battery faults.
Enabled - the B465 sends reports and sets the trouble LED for faults on the tamper
circuit.
Disabled - the B465 does not send reports or set the trouble LED for faults on the tamper
circuit.
Enabled - when there is a fault on the tamper circuit, the B465 sets the trouble output.
Disabled - the B465 does not set the trouble output for faults on the tamper circuit.