Cellular Network Registration; Usb Com Port Error - Bosch Conettix B465 Installation And Operation Manual

Universal dual path communicator
Hide thumbs Also See for Conettix B465:
Table of Contents

Advertisement

Conettix Universal Dual Path Communicator
11.6.7

Cellular network registration

Description:
The B465 is attempting to register on the cellular network. This issue occurs if the registration
never occurred, and can last up to 8 minutes. After 8 minutes, the LEDs change to the double-
flash Radio Registration state. This condition can also happen if only one tower is within RF
range and it has an outage. The module continues to attempt to establish communications.
Solution:
1.
2.
3.
11.6.8

USB COM port error

Description:
COM error occurs when trying to connect to the B465 using the USB serial program. The
following screen shows.
Figure 11.2: COM port error
Solution:
1.
2.
Bosch Security Systems, Inc.
Refer to Wireless Reception Issues if the signal strength is unacceptable.
Replace the SIM card with a known good test card. If the signal strength is acceptable,
confirm that the wireless service provider activated this account and the SIM card
correctly.
If the problem continues, replace the B465.
Click OK.
Click File -> New Connection.
Installation and Operation Manual
Maintenance and troubleshooting | en
2017.11 | 05 | F.01U.311.207