Conettix Universal Dual Path Communicator
Figure 4.12: NON-power limited wiring for a wired transformer
Callout ー Description
1 ー Conduit required for use with external batteries
2 ー Battery terminals. BATTERY+ is non-power limited
3 ーD1640-120WI UL Listed Class 2 Wired Transformer 16.5 VAC, 40 VA, 60 Hz (tuck the
wires behind the battery to ensure the proper clearance)
4 ー 12 VDC sealed lead-acid rechargeable battery (D126/D1218)
5 ー Battery wires (red and black)
6 ー B465 ground wire connection (tuck the wires behind the battery to ensure the proper
clearance)
Battery maintenance
Use sealed lead-acid rechargeable battery (12.0 VDC, 7 Ah to 12.0 VDC, 18 Ah). The B465
supports up to 18 Ah of battery. Replace the batteries every 3 to 5 years.
Record the date of installation directly on the battery.
Caution!
Exceeding the maximum output ratings or installing the transformer in an outlet that is
!
routinely switched off causes heavy discharges. Routine heavy discharges can lead to
premature battery failure.
Bosch Security Systems, Inc.
2
1
3
Installation and Operation Manual
Y
X
COMMUNICATION MODULE 1
SDI2
Device Bus
R Y G B
2.2 k
24 VDC
Line Resistors
or
16.5 VAC
1 COM 2
BATTERY
+
-
18VAC
NO C NC
C
NO
C
NO
12V
1
COM
BATTERY
RELAY 1
RELAY 2
RELAY 3
AUX COM
5
4
Installation | en
MODULE 1
MODULE
RELEASE
ETHERNET
100BASE-T
LINK
USB
SYSTEM TROUBLE
TX
TX
RX
AC
AC
BATTERY
INPUTS
End of
PANEL
PANEL
3 COM 4
LINE 1
LINE 2
PNL LINE 1
PNL LINE 2
2
3
COM
4
6
3