Conettix Universal Dual Path Communicator
10

Output Configuration

10.1

Output 1 (to 3)

Default: Disabled
Selections:
USB Menu Location
[6] Output Configuration > [1,2,3] Input 1 (to 3)
Bosch Security Systems, Inc.
Output 1 - System Trouble
Output 2 - Primary Power Fail
Output 3 - Battery Fault
System Trouble - the B465 activates this output for any failure or trouble condition
configured to activate the trouble LED and output.
Primary Power Fail - the B465 activates this output when the primary power source is
failed.
Panel AC Fail - when a B465 is input configured for Panel AC Fail is shorted, the B465
activates this output.
Battery Fault - when there is a battery fault condition, the B465 activates this output.
Comm Fail - when there is a communication fail condition, the B465 activates this output.
Ethernet Comm Fail - when there is a communication fail condition using the onboard
Ethernet device, the B465 activates this output.
Cellular Comm Fail - when there is a communication fail condition using the a plug-in
cellular device, the B465 activates this output.
Disabled - the B465 does not activate this output.
Installation and Operation Manual
Output Configuration | en
2017.11 | 05 | F.01U.311.207
79