PSTN (Contact ID) over GSM Mode
ID
%1
1=
14=
17=
!
1
Select 3 (PSTN (Contact ID) over GSM) for PSTN over GSM Mode
Table 4.3 PSTN (Contact ID) over GSM Mode SMS Configuration
Multiple SMS Messages (for Messages Longer than 160 Characters)
ID
%1<LF>
1=4020G<LF>
2=secret123<LF>
3=123456,4343<LF>
10=basic.m2m<LF>
11=user@telco.com<LF>
12=password<LF>
15=1<LF>
16=01020304050607080910
111213141516<LF>
Table 4.4 Double SMS Example, Part 1
ID
%2<LF>
14=134<LF>
!
Table 4.5 Double SMS Example, Part 2
4.1.3

Send the Configuration SMS

1.
2.
Bosch Security Systems, Inc.
Description
SMS sequence number 1
Current password (4 to 15 characters); default = 4020G
Control panel bus address 0 to set it to PTSN (Contact ID)
over GSM mode
Communication path:
1 = Both (default)
2 = IP over GPRS
3 = PSTN (Contact ID) over GSM
End of configuration
Description
SMS sequence number
Option bus address
End of configuration
Send the configuration SMS to the SIM card phone number. The transmission might take
several minutes. Because the CONFIG jumper is on, the ITS-DX4020-G waits for an SMS
until a message is received.
Observe the LEDs on the ITS-DX4020-G.
When all of the LEDs start a scrolling pattern, the ITS-DX4020-G is successfully
configured. Refer to Table 4.6 for more information.
Installation and Operation Guide
1
Description
SMS sequence number 1
Current password
New password (case sensitive)
PUK and new PIN to set in SIM
(Access Point Name) APN
GPRS username
GPRS password
Enable AES encryption
Sample AES key
Configuration | en
Sample SMS
%1
1=4020G
14=0
17=3
!
Sample SMS
%1
1=4020G
2=secret123
3=123456,4343
10=basic.m2m
11=user@telco.com
12=password
15=1
16=01020304050607080910111213141516
Sample SMS
%2
14=134
!
F01U163066 | 01 | 2010.05