Valve terminal/valve sensor terminal with field bus connection
Hide thumbs Also See for VIFB-02 Series:
Table of Contents

Advertisement

VIFB8 – 02
Valve
Valve
Festo
location
type
designation
no.
2
single
solenoid
9
double
solenoid
Additional outputs
SA0
SA1
Fig. 5/6: Example 1 – Addressing and activating valves and additional
outputs
Inputs
Designation
Inputs
Valve location no. 2
Inputs
Valve locations no. 9
Fig. 5/12: Example 2 – Addressing and reading inputs
5-10
5. Commissioning
Example 1:
Addressing and activating valves and additional
outputs (SA0 and SA1).
Bit
Remarks
con-
tents
O0.06
1
Valve solenoid coil active
O0.07
X
Output not evaluated
O1.04
0
Upper valve solenoid coil not active
O1.05
1
Lower valve solenoid coil active
O0.00
0
Additional output not active
O0.01
1
Additional output active (24 V DC)
Example 2:
Addressing and reading inputs.
Bit contents
read
I0.06
1
I0.07
0
I1.04
0
I1.05
1
Remarks
No signal
Signal exists
No signal
Signal exists