5. Maintenance and conversion

5.2.1 Dismantling components in valve locations

Festo P.BE-CPV-EN en 0005e
The components on the CPV valve terminal can easily be dis-
mantled for maintenance and conversion work.
Proceed as follows
Loosen the electrical connections
Note the following with the MP, AS-i, and CP connections:
S
Loosen the multipin lug or the AS-i, DI or CP connection
plug and pull it off carefully.
S
Then loosen the four fastening screws in the electrical
sub-base. Pull the sub-base carefully away from the ter-
minal lugs of the valve plates.
S
If necessary, remove the connector plug on the relay out-
puts. Loosen first the locking screws of the upper con-
nector plug. Pull the plug carefully away from the terminal
lugs. Then loosen the lower connector plug in the same
way.
Note the following with the IC connection:
S
In order to dismantle the valve plates, loosen the locking
screws on the connector plugs of the valve plates to be
replaced.
S
Pull the plug and the intermediate plug for the hall cur-
rent reduction carefully away from the terminal lugs. Mark
the sockets.
S
With the CPV valve terminals with pneumatic multipin, we
recommend that you remove the connector plug from
each valve plate.