Festo VIFB-02 Series Manual page 90

Valve terminal/valve sensor terminal with field bus connection
Hide thumbs Also See for VIFB-02 Series:
Table of Contents

Advertisement

VIFB8 – 02
0.00
No.
0
0.01
Fig. 5/2: Outputs of the valve locations
Valve
Valve type
location
no.
2
single solenoid
9
double solenoid
Fig. 5/3: Example – Addressing and activating valves
9706
5. Commissioning
The assignment of the outputs to the relevant
valve location is shown in the diagram below.
Outputs of the valve
locations
0.02
0.04
0.06
0.08
0.10
Valve locations
No.
No.
No.
No.
No.
1
2
3
4
5
0.03
0.05
0.07
0.09
0.11
Outputs of the
valve locations
Example:
Addressing and activating the valves
Output
Bit
Remarks
con-
tents
O0.04
1
Valve solenoid coil active
O0.05
X
Output not evaluated
O1.02
0
Upper valve solenoid coil not active
O1.03
1
Lower valve solenoid coil valve
0.12
0.14
1.00
1.02
No.
No.
No.
No.
6
7
8
9
0.13
0.15
1.01
1.03
5-7

Advertisement

Table of Contents
loading

Table of Contents