4. Installation
The following procedure should be adopted:
1. Bore four holes in the mounting surface. The
distance between the holes depends on the
type of valve terminal/valve sensor terminal
used (specifications of the
given in round brackets).
L
1
Valve terminal/
valve sensor terminal
VIFB-/IIFB-02-1/4(1/8)-4
VIFB-/IIFB-02-1/4(1/8)-6
VIFB-/IIFB-02-1/4(1/8)-8
VIFB-/IIFB-02-1/4(1/8)-10
VIFB-/IIFB-02-1/4(1/8)-12
VIFB-/IIFB-02-1/4(1/8)-14
VIFB-02-1/4(1/8)-16
Fig. 4/2: Fitting the valve terminal/valve sensor
terminal
2. Fasten the valve terminal onto the mounting
surface with 4 hexagon head bolts (M6x60).
The bolts should be tightened in diagonally
opposite sequence.
1
" design are
8
6.8 mm
L
2
Distance between holes
[mm]
L
L
1
2
32 (27.5)
222 (198)
32 (27.5)
288 (252)
32 (27.5)
354 (306)
32 (27.5)
420 (360)
32 (27.5)
486 (414)
32 (27.5)
552 (468)
32 (27.5)
618 (522)