Download Print this page
Festo VTEM Operating Instructions Manual

Festo VTEM Operating Instructions Manual

Motion terminal

Advertisement

Quick Links

VTEM
Motion Terminal
Operating instructions
8179050
2022-06f
[8179052]
Translation of the original instructions
© 2022 all rights reserved to Festo SE & Co. KG
Chrome®, FIREFOX®, INTERNET EXPLORER®, MICROSOFT EDGE® are regis-
tered trademarks of the respective trademark owners in certain countries.
1
About this document
1.1
Applicable documents
All available documents for the product è www.festo.com/sp.
Document
Product
Assembly instructions
CPX, VTEM
Manual
VTEM
Manual
GAMM-A...
Manual
CPX terminal
Application note
VTEM
Tab. 1: Applicable documents
1.2
Product version
This document refers to the following product versions:
Product
Version
VTEM-...
Motion Terminal VTEM from Revision 01
CTMM-S1-C
Controller of the Motion Terminal VTEM from Revision 01
Firmware
Firmware of the Controller CTMM from version 4.24.0
VEVM-S1-27-...
Valve for Motion Terminal VTEM from Revision 01
CTMM-S1-D-8E-M8-3
Digital input module for Motion Terminal VTEM from revision 02
CTMM-S1-A-8E-A-M8-4
Analogue input module for Motion Terminal VTEM from revision 02
– FIREFOX from version 38 (recommended)
1)
Browser
– Chrome from version 64
– INTERNET EXPLORER from version 11
– MICROSOFT EDGE from version 38
1) Use current version.
Tab. 2: Product version
The product version can be identified from the product labelling or with the help
of appropriate Festo software.
Suitable software for determining the product version is available on the Festo
website è www.festo.com/sp.
Information on using the software can be found in the integrated Help function.
There may be an updated version of this document for this or later product
versions è www.festo.com/sp.
1.3
Product labelling
The product labelling is explained in the product manual è 1.1 Applicable docu-
ments.
Festo SE & Co. KG
Ruiter Straße 82
73734 Esslingen
Deutschland
+49 711 347-0
www.festo.com
Contents
System, function, parameteri-
sation
Motion App
System
Various contents
è www.festo.com/sp è VTEM
è Expert knowledge
2
Safety
2.1
Safety instructions
– Observe identification on the product.
– Before working on the product, switch off the power supply and secure it
against being switched on again.
– In the power-free status (normal position), compressed air may be trapped
between the working air ports and connected drives. To avoid accidental move-
ments of the connected drives due to leakage, carry out the following steps
before switching off the supply voltage:
– Bring the system into the exhausted state è App control (app control):
"Exhaust".
– Disconnect the compressed air supply and, if applicable, the vacuum supply.
– During rapid movement of heavy masses, especially during braking, the pres-
sure in the pneumatic system can increase and damage pneumatic compo-
nents.
– Set up the pneumatic installation with sufficient load reserve for the applica-
tion.
– Store the product in a cool, dry environment protected from UV and corrosion.
Keep storage times short.
– Comply with the handling specifications for electrostatically sensitive devices.
– Observe tightening torques. Unless otherwise specified, the tolerance is
± 20 %.
2.2
Intended use
The product is intended for controlling pneumatic drives and for implementing
motion tasks (Motion Apps).
The product may only be used as follows:
– Use only in an industrial environment: outside industrial environments, e.g.
in commercial areas and mixed commercial and residential areas, action to
suppress interference may be required.
– Use exclusively in combination with modules and components that are certified
for the specific product variant and have been tested and approved by Festo.
– Use in technically perfect original status without unauthorised modifications.
Only the conversions or modifications described in this and the further appli-
cable documents are permitted.
2.3
UL/CSA Certification
In combination with the UL inspection mark on the product, the information in this
section must also be observed in order to comply with the certification conditions
of Underwriters Laboratories Inc. (UL) for USA and Canada.
UL approval information
Product category code
File number
Considered standards
UL mark
Tab. 3
Only for connection to a NEC/CEC Class 2 supply.
WARNING
The unit shall be supplied by a power source which fulfils the requirements on a
limited-energy circuit in accordance to IEC/EN/UL/CSA 61010-1 or on a Limited
Power Source (LPS) in accordance to IEC/EN/UL/CSA 60950-1 or IEC/EN/UL/CSA
62368-1 or a Class 2 circuit in accordance to NEC or CEC.
3
Additional information
– Contact the regional Festo contact if you have technical problems
è www.festo.com.
– Accessories and spare parts è www.festo.com/catalogue.
4
Product overview
The product is a component of a CPX terminal, forms its pneumatic side, and is a
platform for execution of Motion Apps.
QUYX, QUYX7
E322346
UL 61010-1
CAN/CSA C22.2 No. 61010-1

Advertisement

loading

Summary of Contents for Festo VTEM

  • Page 1 – Use exclusively in combination with modules and components that are certified Applicable documents for the specific product variant and have been tested and approved by Festo. – Use in technically perfect original status without unauthorised modifications. Only the conversions or modifications described in this and the further appli- All available documents for the product è...
  • Page 2 The product can consist of the following modules, depending on the configuration ordered: Fig. 3: LED display on valve Meaning (red) Valve faults: VTEM manual è 1.1 Applicable documents (blue) Operation/update Fig. 1: Product design Tab. 6: LED display on valve...
  • Page 3 • Virtual private Network (VPN) • Security at physical access level (port security) The function scope of the Motion Terminal VTEM is dependent on the scope of For additional information è Guidelines and standards for security in information the licensed Motion Apps. For many Motion Apps, the number of licences required technology, e.
  • Page 4 The drive cannot be controlled as intended. • Use only sensors intended for use with the Motion Terminal VTEM. 1. Push tubing into or over the connection of the tubing fitting up to the stop. 2. For lock ring fittings or barbed hose fittings: Pull the lock ring or tubing clip over the tubing connection and tighten.
  • Page 5 Option for using demo licences Note the time remaining for the active. demo period flashes Operation of the WebConfig interface is described in the “Motion Terminal VTEM, Configuration inactive: no – WebConfig interface” QuickGuide è 1.1 Applicable documents. access via the WebConfig inter- face.
  • Page 6 LED on valve Modification 11.1 Tightening Torques LED valve (blue/red) Meaning Measure Valve faults Check error log. VTEM manual è 1.1 Applicable documents. Load voltage supply U Check connection of the power applied. supply U red light Error-free operation –...
  • Page 7 Digital input module (plus intrinsic con- [mA] sumption of the sensors) Functional earth (FE) Via functional earth connection of the CPX terminal and functional earth connection at the VTEM terminal strip Tab. 26: Power supply Approvals CE marking in accordance with EU EMC Direc-...