3. Technical description
Electromagnetic
compatibility (EMC):
Resistance to interference
• tested as per
EN 50082-2
Spark suppression
• tested as per EN 55011
Protection against electric
shock (protection against
direct and indirect contact as
per EN 60204-1/IEC 204)
Additional outputs/
installation terminal
Loading per
• additional output
Electronic fusing
(short circuit, overload)
• Trigger current
• Response time
(short circuit)
Inputs/valve sensor terminal
Logic level
• ON
• OFF
Voltage range
Current capacity (at 24V)
(Current from sensor to input)
Response delay of valve
sensor terminal inputs (at 24 V)
Common fuse for operating
voltage supply to sensors
*) The valve terminal with FB8-02 can also be used in a
residential environment with individual authorization
(residential, business, commercial environment, small
firms).
Limit value class A *)
by means of PELV
power units (protected
extra low voltage)
max. 0.5 A
(Bulbs max. 10 W
because of PTC
resistor characteristics
max. 1 A
max. 1 s
12 V
7.5 V
0 V ... 30 V
typ. 9 mA
typ. 5 ms
4A, slow-blowing