SECTION 582-210-700
POWER SUPPLY VOLTAGE
Requirement
Voltage reading should be -24 V dc
±.
1
%.
Tractor Feed Printers
CABLE AND PLUG CONNECTIONS
Remove printer logic circuit card.
Plug the 402779 line cord with switch into the 402781 line cord adapter. Plug the 402781 adapter into
Jl13 connector, the top rack and panel connector located on the left rear side of the printer.
With the switch on the 402779 line cord in the OFF position, plug the line cord into a three-prong
grounded power source.
Plug the 402782 jumper plug into Jl14 connector, located immediately below Jl13 on the left rear side
of the printer.
~~o\--.1
11:J
Friction Feed Printers
CABLE AND PLUG CONNECTIONS
Remove printer logic circuit card.
402781 LINE CURD
402779
TO
CORD
ADAPTO~
LINE
.11I:l\..
~
W/SWITCH
TO
.11 J 4
~
~
Plug the 402779 line cord with switch into the ac power connector (3-pin connector), J100, located at
the left rear side of the printer. Verify that the switch is in the OFF position. Plug the other end of the
402779 line cord with switch into a three-prong grounded power source.
Plug the 402780 jumper plug into PI06 located at the right rear top side of the printer.
PI06
Page 56
402780
JUMPER PLUG
~
..
'
~