SECTION 582-210-700
RIBBON GUIDE
(40P253 Forms Access Printer)
Requirement
RIBBON-PAPER
SHIELD
BRACKET
RIBBON-PAPER
SHIELD BRACKET
MOUNTING SCREWS
PRINT
HAMMER
BANK
With the 402617 gauge held against the backup bar of the carrier track assembly there should be
Min Some -- Max 0.006 inch
between the gauge points and the ribbon-paper shield.
Install 402617 gauge. See Page 24.
To Adjust
With the ribbon-paper shield bracket mounting screws friction tight, position the shield bracket to
meet requirement. Tighten two mounting screws.