ISS 3, SECTION 582-210-700
FORM-OUT CONTACT GAP (Preliminary) (Tractor Feed and Forms Access Printers)
Requirement
With form-out contacts fully open, gap between contacts should be
Min 0.020 inch --- Max 0.030 inch.
To Check
Depress the form selector lever.
FORM SELECTOR
LEVER
To Adjust
Form contact spring to meet requirement.
Note:
This contact is manufactured within the
requirement and will remain so unless one or
both contact springs have been deformed. If
adjustment is required, adjust the spring which
shows sign of such deformation.
FORM SELECTOR
FORM-OUT
LEVER GUIDE
CONTACT
FORM SELECTOR LEVER GUIDE (Tractor Feed and Forms Access Printers)
Requirement
There should be up to 0.005 inch clearance between guide and form selector lever and selectorleyer
must operate freely.
To Check
FORM SELECTOR
LEVER
GUIDE
\~~
GUIDE MOUNTING
SCREWS
FORM-OUT CONTACT
Form selector biased toward contact housing and selector lever operated through its entire range of
motion.
To Adjust
Loosen the guide mounting screw friction tight and position guide to meet requirement. Tighten
mounting screws.