Bell DATASPEED 40 Adjustments And Lubrication page 15

Table of Contents

Advertisement

ISS 3, SECTION 582-210-700
PAPER-OUT SWITCH (Early and Late Design) (Cont)
(80-Column Tractor Feed Pinter)
(Late Design)
Requirement
With a flat plate positioned over the opening in the paper guide and the paper-out actuator biased
against the flat plate, a test lamp should be ON or an ohmmeter should indicate a closed circuit. Passing
a 0.010 inch flat gauge between the actuator and the flat plate should cause the lamp to go OFF or an
ohmmeter to indicate an open circuit.
Note:
When the 0.010 inch flat gauge and the flat plate are removed and the flat plate is again posi-
tioned over the paper guide opening, the lamp should be ON or an ohmmeter should indicate a closed
circuit.
To Adjust
Place a lamp or ohmmeter across pins 1 and 3 of connector J114 on 40P150 through 40P153 printers
or across pins 7 and 10 of connector P109 on 40P154 printer. With the clamp screw friction tight and
a flat plate over the paper guide opening, move the switch in the direction indicated by
(2) -
until the
end of adjustment range is reached. Position the 0.010 gauge between the actuator and the flat plate
and move the switch in the direction indicated by
CD
-until lamp goes OFF or ohmmeter indicates an
open circuit. Tighten clamp screw and recheck requirement.
CLAMP SCREW
(Side View)
0 -
0 -
o
,:~~
MOUNTI~G /
SCREWS/
MOUNTING
BRACKET
Just Underflush
to
0.010 Inch
Underflush
,-
I
FLAT PLATE
1,,--
EARLY DESIGN
OPENING
REDESIGNED
OPENING
(Front View)
\
\
~\
PAPER-OUT
ACTUATOR
Page 15