SECTION 582-210-700
FLAG SENSOR GAP
Requirement
There should be
Min 0.010 inch
clearance between the closest flag and
the magnetic sensor pole piece and
Max 0.030 inch
clearance between any flag and the
magnetic sensor.
To Adjust
Loosen sensor locking screw. Adjust
gap to meet requirement. Tighten
locking screw.
(Front View)
Note:
It is preferable to use non-
magnetic gauges to check requirement.
Steel gauges are attracted by the sensor
magnet making it difficult to gauge
the adjustment.