Calibration Screen
Figure 19.
1.
2.
3.
4.
Touch crosshair to calibrate
800 x 480
Touch Calibration Screen
Press and hold down the recessed front-panel menu button (see figure 5, 
page 12) for at least 3 seconds.
Release the button. The calibration screen opens to show cross-hairs (see figure 19,
above).
Follow the on-screen instructions until all five sets of cross-hairs have been calibrated (one
in each corner and a fifth in the center of the screen).
The touchpanel exits the calibration screen once the calibration process is completed.