Supplementary system components
6.5 CX32-2 controller extension
6.5.2.3

DRIVE-CLiQ interface

Table 6- 21
Dust protection blanking plugs for sealing unused DRIVE-CLiQ ports:
6.5.2.4

Digital I/Os (X122)

Interface characteristics
Sensors and actuators can be connected to the X122 connector via digital inputs and
outputs.
Table 6- 22
Characteristics
Connector type
Connectable cable types:
- Rigid
- Flexible
- Flexible, with end sleeve without plastic sleeve
- AWG/kcmil
Stripped length
Tool
Max. cable length
Max. current carrying capacity (ground)
118
DRIVE-CLiQ interface X100 – X103
Pin
1
2
3
4
5
6
7
8
A
B
Three blanking plugs contained in the CX32-2 scope of delivery
Blanking plugs (50 pcs) order number: 6SL3066-4CA00-0AA0
X122 wiring
Signal name
TXP
TXN
RXP
Reserved, do not use
Reserved, do not use
RXN
Reserved, do not use
Reserved, do not use
+ (24 V)
M (0 V)
Technical specifications
Transmit data +
Transmit data -
Receive data +
Receive data -
Power supply
Electronic ground
Type
Mini Combicon
Conductor cross-sections:
0.2 mm
to 1 mm
2
2
0.2 mm
to 1.5 mm
2
2
0.25 mm
to 1.5 mm
2
24 to 16
8 mm
Screwdriver 0.4 x 2.0 mm
30 m
6 A
2
SIMOTION D4x5-2
Manual, 02/2012