14 ERROR CODE
error code
item
(SD0)
Power supply
1500
Battery
1600
Diagnosis
error code
timing
1500
Always
1600
Always

14.2 System setting errors

7 segments
Error name
LED
AMP No. SETTING
SYS.SET DATA ERR
AXIS No. ERROR
ROM ERROR1
ROM ERROR2
"AL" 3 times
flashes
ROM ERROR3(**)
ROM ERROR4(**)
Note-1 : ["AL" flashes 3 times
Note-2 : This error code is stored in Self-diagnosis error (SD0).
Note-3 : When error code 10014 occurs. System setting error flag (M2041) turns ON and the applicable
error name shown above is displayed on the error list monitor of the MT Developer2.
Below table shows Self-diagnosis errors.
Table 14.1 Self-diagnosis errors
error message
data(SD5 to SD15)
DC DOWN
BATTERY ERROR
Drive name
Contents and causes
24VDC power supply has stopped supplying power.
(1) Voltage of the CPU has dropped below stipulated level .
(2) The lead connector of CPU battery has not been
installed.
Below table shows System setting errors
Table 14.2 System setting error
Error code
(Note-1)
(Note-2)
• Servo axis is not set in system setting.
• System setting data is not written.
•System setting data is written before "Relative check"
Or It is written with an error of "Relative check".
• System setting data is not written.
• Operating system software data type
written to ROM is different.
• Data is not written to ROM.
10014
• ROM data size is wrong.
(Note-3)
•Execute ROM write again.
•Check for version adjustment
of the motion controller, MT Developper2
and operating system software.
• ROM data is wrong.
•Execute ROM write again.
•Check for version adjustment of
the motion controller, MT Developper2
and operating system software.
"L01" turns on ] is continuously repeated. (No error code on 7-segments LED.
Common Error
Individual Error data
(SD16 to SD26)
error cause
14 - 2
7 segments
Operating status
LED
of CPU
No error
Continue
"BT1" is on
Continue
"BT2" is on
Corrective action
Check the power supply.
(1) Replace the battery
(2) Install a lead connector.
Operation at
Check timing
error occurrence
Cannot be
When the
started.
power is turned
(Motion
ON/ the key is
controller
reset.
system setting
error).

Hide quick links: