4
Measurement Operations & Settings

Triggering - The TRIGger Subsystem

Command:
:TRIGger
Syntax:
:TRIGger<wsp>NODEA|1|NODEB|2
Description:
Generates a hardware trigger.
Parameters:
1 or NODEA:
2 or NODEB:
A hardware trigger cannot be effective in the DISabled triggering mode but can be effective in DEFault, PASSthrough or
LOOPback triggering modes, see
Response:
None
Example:
:trig 1
Command:
:TRIGger[n]:DELay?
Syntax:
:TRIGger[n]:DELay?
Description:
Returns factor for delay. Effective trigger delay time = factor/32 Mhz
Parameters:
None
Response:
Factor
Example:
:trig1:del? → +0
Command:
:TRIGger[n]:DELay
Syntax:
:TRIGger[n]:DELay<wsp><value>
Description:
Defines factor for delay. Effective trigger delay time = factor/32 Mhz. That means, trigger event is excuted after specified
time after input trigger.
90
The TRIGger Subsystem allows you to configure how the instrument reacts
to incoming or outgoing triggers.
Is identical to a trigger at the Input Trigger Connector.
Generates trigger at the Output Trigger Connector.
:TRIGger:CONFiguration
Keysight N774xC Series Multiport Power Meter Programming Guide
on page 94 for information on triggering modes.