5.4
Installation
NOTE!
If both channels are used, a second cable with a further 26-pole sub D connector
must be led through the 25-pole sub D connector (cable is splitted).
View on solder pin side
14
1
25
13
Æ 0.34 mm²
1
Æ 0.34 mm²
2
3
4
5
15
16
17
Æ 0.34 mm²
9
Æ 0.34 mm²
10
11
12
13
23
24
25
Figure 6:
NOTE!
The connection cable must be manufactured according the above mentioned instruc-
tion with the
The cable is not working with another pin assignment!
30
Instruction handbook b maXX 5000 add-on module MOD
Document No.: 5.19015.01
of 90
1
2
8
9
Channel 1
6
7
5
4
1
2
8
9
Channel 2
6
7
5
4
View on solder pin side

Connection cable IEE with b maXX 5000

ZPin assignment IEE–
on page 29!