Process Data Mapping - Baumuller b maXX 5000 Series Instruction Handbook Manual

Add-on modules modbus/tcp mod
Hide thumbs Also See for b maXX 5000 Series:
Table of Contents

Advertisement

7.3
Process data (cyclic communication)
7.3.1

Process data mapping

The process data mapping of the b maXX 5000 can be configured by the Modbus register
210 - 337 (actual process data mapping) and register 410 - 537 (set process data map-
ping). The mapping configuration sets the parameters mapped on the Modbus register
addresses 2 - 65) (actual process data) and 102 - 165 (set process data).
The mapped parameters can be read or written via the process data register in state Pre-
operational.
The writing of mapping register is only possible in state Pre-operational.
The mapped parameter is written to via function block (FB), parameter number (PNR),
instance of the function block (FBI) and axis number. All mapped parameters are wirtten
to in a list for actual process data (actual process data mapping) and another list for set
process data (set process data mapping):
Actual process data mapping: Register 210 - 337
List of the parameter, which are mapped to the actual process data
Set process data mapping: Register 410 - 537
List of the parameter, which are mapped to the set process data
The last mapped parameter is followed by an FB value of 0. No FB value of 0 is allowed
if all possible parameters should be mapped
An invalid mapping configuration is displayed not before the status is changed to Opera-
tional. An invalid configuration is shown by the set bit 5 in status word
page 53) and a corresponding error code can be read in register address 200 - 201 (see
ZGeneral errors–
16 actual and set values can be mapped in b maXX 5000 single axis unit
32 actual and set values can be mapped in b maXX 5000 double axis unit
46
Instruction handbook b maXX 5000 add-on module MOD
Document No.: 5.19015.01
of 90
n FB =
Register 210 + (PDO_number * 4)
n PNR =
Register 211 + (PDO_number * 4)
n FBI =
Register 212 + (PDO_number * 4)
n AXIS =
Register 213 + (PDO_number * 4)
n FB =
Register 410 + (PDO_number * 4)
n PNR =
Register 411 + (PDO_number * 4)
n FBI =
Register 412 + (PDO_number * 4)
n AXIS =
Register 413 + (PDO_number * 4)
on page 58).
(ZStatus word–
Baumüller Nürnberg GmbH
on