General Description; Configure Ip Address - Baumuller b maXX 5000 Series Instruction Handbook Manual

Add-on modules modbus/tcp mod
Hide thumbs Also See for b maXX 5000 Series:
Table of Contents

Advertisement

7.1

Configure IP address

The IP address either can be configured via ProDrive permanently or defined via the field-
bus by DHCP or BOOTP.
Static IP addresses can be assigned via the ProDrive only.
Via the fieldbus statical IP addresses as well as DHCP or BOOTP addresses can be as-
signed.
If the address is accepted by ProDrive or is configured via the fieldbus depends of the
host IP address which was configured in ProDrive.
If host IP unequal 0
If host IP equals 0
Description of Host-IP:
Host-IP = A combination of network mask and IP address.
For example network mask = 255.255.0.0; IP address = 192.168.12.56  Host IP =
12.56
NOTE
The IP settings that are in ProDrive are evaluated at startup, only. Therefore all set-
tings here must be saved via ProDrive and the device must be started again.
A valid Gateway address must be assigned in parameter 131.16.
G
7
Instruction handbook b maXX 5000 add-on module MOD
D
ENERAL
ESCRIPTION
The ProDrive settings are used for MOD
The MOD- IP settings must be made via the
fieldbus. Initially DHCP is used
Document No.: 5.19015.01
41
of 90

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bmaxx5000Bmaxx5500

Table of Contents