3.2
Electrical data
3.2
Electrical data
3.2.1
Modbus/TCP, 2 channels
Supply voltage (external supply)
Supply current (external supply)
Signal level: output high voltage at I
Signal level: output high voltage at I
Output frequency, track signals
Switching time: rising time
Switching time: dropping time
Delay time
Power input
Current output driver
The mentioned timings are available at the module output. When selecting a cable in or-
der to transmit the signals to an adequate evaluation unit, it must be considered, that a
real cable can reduce the maximum transferable output frequency by its attenuation
(change of specified signal performance).
TTL square wave
Two TTL square wave pulse cycles A and B with a 90° electrical phase shifting and their
pulse cycles
inverted pulse cycles A and B as also a zero pulse 0 with the inverted signal 0 are avail-
able by way of output signals.
Figure 1:
18
Instruction handbook b maXX 5000 add-on module MOD
Document No.: 5.19015.01
of 90
Pulse cycles, incremental encoder emulation IEE
5 V
max. 100 mA (without load)
= - 20 mA
2,5 V
0H
= + 20 mA
0,5 V
0L
max. 500 kHz
< 50 ns
< 50 ns
It
I = 1
d
0,525 W
max. 15 mA
±
5 % (without load)
b
50 ns
Baumüller Nürnberg GmbH