Figure 42. Installing the left control panel
Next steps
1.
Replace the cooling fan
2.
Replace the air
shrouds.
3.
Replace the support
bar.
4.
Replace the front
bezel.
5. Follow the procedure listed in

Removing the right control panel

Prerequisites
1. Follow the safety guidelines listed in
2. Follow the procedure listed in
3.
Remove the front
bezel.
4.
Remove the support
bar.
5.
Remove the air
shroud.
6.
Remove the cooling fan
Steps
1. Disconnect the VGA cable from the system board.
2. Lift the cable latch and disconnect the control panel cable from the system board connector.
3. Using a Phillips #1 screwdriver, remove the screws that secure cable cover and remove it from the system.
4. Remove the screws that secure the control panel and ribbon cable to the system.
5. Holding the control panel and ribbon cable, remove the control panel and ribbon cable away from the system.