Flowchart To Remedy The Troubles - Renesas M30290T-EPB User Manual

Emulation probe for m16c/26a, 28, 29 group mcus
Table of Contents

Advertisement

M30290T-EPB User's Manual

6.1 Flowchart to Remedy the Troubles

Figure 6.1 shows the flowchart to remedy the troubles from when power to the emulator is activated until the emulator
debugger starts up. Check this while the user system is disconnected. For the latest FAQs visit the Renesas Tool
Homepage.
Turning on PC7501
Front panel LED
of PC7501
Init dialog box of
emulator debugger displayed
MCU Setting dialog box
of emulator debugger displayed
Program window of
emulator debugger displayed
Emulator debugger startup completed
Figure 6.1 Flowchart to remedy the troubles
http://www.renesas.com/en/tools
Not normal
Normal
1. Check emulator system connections.
See, "3.3 Connecting the PC7501" (page 30).
2. Redownload the firmware.
See "4.2 Downloading Firmware" (page 40).
3. Restart the PC7501 system.
Not normal/Error displayed
1. Check the operating environment etc. of the
Normal
emulator debugger.
See the user's manual of the emulator debugger.
2. Reinstall the emulator debugger.
Not normal/Error displayed
See "6.2 (2) MCU Setting Dialog Box Does Not Appear at
Normal
Debugger Startup" (page 52).
Error displayed
Normal
See "6.2 (3) Errors Occur at Debugger Startup" (page 52).
( 50 / 58 )