Quick Links

To our customers,
st
On April 1
, 2010, NEC Electronics Corporation merged with Renesas Technology
Corporation, and Renesas Electronics Corporation took over all the business of both
companies. Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry.
Old Company Name in Catalogs and Other Documents
Renesas Electronics website:
http://www.renesas.com
st
April 1
, 2010
Renesas Electronics Corporation

Advertisement

Table of Contents
loading

Summary of Contents for Renesas Emulation Pod forM16C/20 Series M30200T-RPD-E

  • Page 1 On April 1 , 2010, NEC Electronics Corporation merged with Renesas Technology Corporation, and Renesas Electronics Corporation took over all the business of both companies. Therefore, although the old company name remains in this document, it is a valid Renesas Electronics document. We appreciate your understanding.
  • Page 2 Renesas Electronics. Renesas Electronics shall not be in any way liable for any damages or losses incurred by you or third parties arising from the use of any Renesas Electronics product for an application categorized as “Specific”...
  • Page 3 M30200T-RPD-E User’s Manual Emulation Pod forM16C/20 Series Rev.1.00 2003.09...
  • Page 4 • These materials are intended as a reference to assist our customers in the selection of the Renesas Technology product best suited to the customer's application; they do not convey any license under any intellectual property rights, or any other rights, belonging to Renesas Technology Corporation, Renesas Solutions Corporation or a third party.
  • Page 5: Precautions For Safety

    Preface The M30200T-RPD-E is an emulation pod main unit for M16C/20 Series of Renesas 16-bit microcomputers. The M30200T-RPD-E is used by connecting to the pod probe M302xxT-PRB and the PC4701 emulator main unit, and is controlled by the emulator debugger.
  • Page 6: Table Of Contents

    Contents Summary ... 6 Terminology ... 7 Things to Check When Unpacking ... 8 Chapter 1. Precautions for Safety ... 9 1.1 Safety Symbols and Meanings ... 9 WARNING CAUTION IMPORTANT Chapter 2. Introduction ... 15 Chapter 3. Specifications ... 16 Chapter 4.
  • Page 7 Chapter 6. External Dimensions ... 25 Chapter 7. Maintenance and Warranty ... 27 7.1 Maintenance ... 27 7.2 Warranty ... 27 7.3 Repair Provisions ... 27 7.4 How to Request for Repair ... 28 Chapter 8. Troubleshooting ... 29 ( 5 / 32 )
  • Page 8: Summary

    Summary Chapter 1. Precautions for Safety This chapter describes the precautions which should be taken in order to use M30200T-RPD-E safely and properly. Refer to each manual of the pod probe, the emulator main unit and the emulator debugger for their precautions. Chapter 2.
  • Page 9: Terminology

    Emulator main unit PC4701 This means a generic name for emulators for 8 and 16-bit MCUs. For details on specific models of PC4701, visit Renesas Tools Homepage at http://www.renesas.com/en/tools Emulation pod main unit This means M30200T-RPD-E (this product). This emulation pod main unit is for M16C/20 series MCUs.
  • Page 10: Things To Check When Unpacking

    Things to Check When Unpacking The M30200T-RPD-E consists of the following parts and manuals. When unpacking, check to see if your M30200T-RPD-E package contains all of these items. Type name M30200T-RPD-E FLX120-RPD FLX64-PRB OSC-3 (10 MHz) OSC-2 (32 MHz) OSC-2 M30200T-RPD-E English user's manual M30200T-RPD-E...
  • Page 11: Chapter 1. Precautions For Safety

    Chapter 1. Precautions for Safety In both the user's manual and on the product itself, several icons are used to insure proper handling of this product and also to prevent injuries to you or other persons, or damage to your properties. This chapter describes the precautions which should be taken in order to use this product safely and properly.
  • Page 12: Warning For Use Environment

    Warning for Installation: • Do not set this product in water or areas of high humidity. Make sure that the emulation pod main unit does not get wet. Spilling water or other liquids into the emulation pod main unit can cause an unrepairable damage.
  • Page 13: Important

    Notes on PC4701 Emulator Main Units: • EMI standards are not met when this product is used with the PC4700H or PC4700L emulator main unit. • The PC4700H emulator main units whose serial number ends with a number cannot be used with M30200T-RPD-E.
  • Page 14: Notes On Connecting Pod Probe And Pitch Converter Board

    Notes on Connecting Pod Probe and Pitch Converter Board: • Prepare the right pod probe for your MCU. Without a pod probe this product cannot be used. • When connecting the pod probe and the pitch converter board, be careful not to forcibly press the connector top of the converter board.
  • Page 15: Note On Address 0 Access

    Note on Address 0 Access: • With the M16C/20 series MCU, when a maskable interrupt is generated, the interrupt data (interrupt No. and interrupt request level) stored in address 0 is read out. Also, the interrupt request bit is cleared when address 0 is read out. Consequently, when the address 0 read-out instruction is executed or when address 0 is read out in the cause of a program runaway, a malfunction occurs in that the interrupt is not executed despite the interrupt request, because the request bit of the highest priority interrupt factor enabled is cleared.
  • Page 16: Note On Stack

    Note on Stack: • This product uses up to 8 bytes for stack. Note on BRK Instruction: • BRK instruction cannot be used. Note on Software Break and Hardware Break: • A software break and a hardware break cannot be used simultaneously. If they are used simultaneously, the emulation pod main unit may not work properly.
  • Page 17: Chapter 2. Introduction

    Chapter 2. Introduction M30200T-RPD-E is used by connecting to the PC4701 emulator main unit. Figure 2.1 shows the system configuration. Figure 2.1 System configuration Products (1) to (4) shown in Figure 2.1 are included with this product. (1) M30200T-RPD-E (Emulation pod main unit) This emulation pod main unit contains emulation memory and debugging functions.
  • Page 18: Chapter 3. Specifications

    Chapter 3. Specifications Table 3.1 lists the specifications of M30200T-RPD-E. Table 3.1 Specifications of M30200T-RPD-E Usable emulator main unit Usable MCU Usable MCU mode Emulation memory Clock Power supply range Stack capacity used for emulator Suspended cycles in run-time debug Power supply to emulation pod Operating temperature range Storage temperature range...
  • Page 19: Chapter 4. Setting Up

    Chapter 4. Setting Up 4.1 Removing the Upper Cover If you need to change the input frequency, remove the upper cover of the product to change the configuration. (1) Remove the four screws of both sides and lift off the upper cover. (see Figure 4.1) (2) Change the input frequency following the instructions shown below.
  • Page 20: Setting Oscillation Frequency

    4.2 Setting Oscillation Frequency When you are using the emulation pod main unit's internal oscillator, see (1) below, and when you are using the target system's oscillator, see (2) on page 21. (1) Using emulation pod main unit's oscillator M30200T-RPD-E is available with two types of internal oscillator circuits: •...
  • Page 21 Figure 4.3 shows the OSC-2 circuit. Use the circuit constants recommended by the manufacturer of the oscillator. X1 ,X 2 * X1: 5.08-mm-pitch 2-pin oscillator X2: 2.54-mm-pitch 2-pin oscillator X3: 2.54-mm-pitch 3-pin oscillator Figure 4.3 Circuit of oscillator board OSC-2 IC1: Inverter (Unbuffer) ( 19 / 32 ) J1-3...
  • Page 22 How to replace the oscillator circuit board is shown in Figure 4.4 below. Figure 4.4 Replacing small oscillator circuit boards (1) Unscrew the screw securing the oscillator circuit board. (2) Lift off the OSC-3 board. (3) Mount the J1 connector of the OSC-2 board into the J5 connector of the M30200T-PRT board.
  • Page 23 (2) Using target system's oscillator a. To operate the emulator with an external clock, construct the oscillation circuit shown in Figure 4.5 in the target system and input the oscillation output at 40-60% duty into the Xin (Xcin) pin. b. Make note of the fact that in the oscillation circuit shown in Figure 4.6 where a resonator is connected between the Xin (Xcin) and Xout (Xcout) pins, oscillation does not occur because a flexible cable, buffer IC and other devices are used between the evaluation MCU and the target system.
  • Page 24: Chapter 5. Connection

    Chapter 5. Connection 5.1 Connection to the Emulator Main Unit Use the FLX120-RPD 120-pin flexible cable (included with the package) to connect the emulator main unit and M30200T-RPD-E. Figure 5.1 shows how to connect the emulator main unit and FLX120-RPD. Install the FLX120-RPD connector (emulator PC4701 side) on the cable connector of the PC4701.
  • Page 25: Connection To The Emulation Pod

    5.2 Connection to the Emulation Pod Attach the FLX120-RPD to M30200T-RPD-E, then secure them with the screws. Figure 5.2 shows how to connect M30200T-RPD-E and FLX120-RPD. Figure 5.2 Connecting emulation pod and FLX120-RPD Caution Note on Connecting the Cable: • Be sure to turn off the power before making connections. Otherwise, the internal circuits may be damaged.
  • Page 26: Connection To The Pod Probe

    5.3 Connection to the Pod Probe The emulation pod for M16C/20 Series consists of the M30200T-RPD-E emulation pod main unit and the M302xxT-PRB pod probe. Figure 5.3 shows how to connect the M302xxT-PRB pod probe. And Figure 5.4 shows how to remove it. Figure 5.3 Connecting the M302xxT-PRB pod probe Figure 5.4 Removing the M302xxT-PRB pod probe Note on Connecting the Cable:...
  • Page 27: Chapter 6. External Dimensions

    Chapter 6. External Dimensions Figures 6.1 shows external dimensions of M30200T-RPD-E. Unit: mm Figure 6.1 External dimensions of M30200T-RPD-E ( 25 / 32 )
  • Page 28 Figures 6.2 shows external dimensions of the FLX64-PRB pitch converter board for connecting to the pod probe. Unit: mm Figure 6.2 External dimensions of FLX64-PRB ( 26 / 32 )
  • Page 29: Chapter 7. Maintenance And Warranty

    Chapter 7. Maintenance and Guarantee 7.1 Maintenance If dust or dirt collects on any equipment of your emulation system, wipe it off with a dry soft cloth. Do not use thinner or other solvents because these chemicals can cause the equipment's surface coating to separate.
  • Page 30: How To Request For Repair

    After checking the contents of fault, the distributor should please send the faulty product along with the Repair Request Sheet to Renesas Solutions Corp. When the faulty product is repaired, it will be returned to the customer at the earliest convenience.
  • Page 31: Chapter 8. Troubleshooting

    Chapter 8. Troubleshooting When the M30200T-RPD-E does not work properly, check the items listed below. (1) The emulator main unit cannot be powered up. Check to see if the AC power cord is firmly plugged into the receptacle. Check to see if the AC power 3P-2P converting connector is firmly connected. (2) The M30200T-RPD-E does not start up when the target system is connected with the PC4701 system.
  • Page 32 MEMO ( 30 / 32 )
  • Page 33 M30200T-RPD-E User's Manual Rev.1.00 September 1, 2003 REJ10J0264-0100Z COPYRIGHT ©2003 RENESAS TECHNOLOGY CORPORATION AND RENESAS SOLUTIONS CORPORATION ALL RIGHTS RESERVED...
  • Page 34 M30200T-RPD-E User’s Manual 1753, Shimonumabe, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8668 Japan REJ10J0264-0100Z...

Table of Contents