5.2 Connection Diagram

Figures 5.1 shows a connection diagram of the M30290T-EPB. This connection diagram mainly shows the interface
section. The circuits not connected to the user system such as the emulator's control system are omitted. The signals not
shown in Figure 5.1 connect the evaluation MCU and the user system directly. Table 5.2 shows IC electric
characteristics of this product for reference purposes.
IC11
P90--P93, P95--P97
Figure 5.1 Connection diagram
Table 5.2 Electrical characteristics of the 74HC4066
Symbol
R
ON resistor
ON
∆R
ON resistor difference
ON
I
Leak current (Off)
OFF
I
Leak current (On, output: open)
IZ
P00--P07
P10--P17
P20--P27
P30--P37
P60--P67
P70--P77
P80--P84
P100--P107
P85/NMI*
*
P86/Xcout
P87/Xcin
*
Xout
M16C/29
*
Emulation
Mode
*
*
*: Connected to the inside of the emulator
Item
Vcc=4.5V
Vcc=4.5V
Vcc=12.0V
Vcc=12.0V
510kΩ
Vcc
74HC4066
74HC4066
510kΩ
Vcc
74HC4066
74HC4066
510kΩ
Vcc
510kΩ
Vcc
Standard values
Condition
Min.
-
-
-
-
( 45 / 58 )
Chapter 5. Specifications
P00--P07
P10--P17
P20--P27
P30--P37
P60--P67
P70--P77
P80--P84
P90--P93, P95--P97
P100--P107
P85/NMI*
P86/Xcout
P87/Xcin
Xout
CNVss
RESET*
Xin
Standard
Max.
96
200
10
-
-
±1
-
±1
Unit
µA

Advertisement