Handling

4.1

Transport

l
l
l
l
The servo amplifiers contain electrostatically sensitive components, that can be
damaged by incorrect handling. Discharge yourself before touching the servo
amplifier. Avoid contact with highly insulating materials, such as artificial fabrics
and plastic films. Place the servo amplifier on a conductive surface.
l
4.2

Packaging

l
l
l
4.3

Storage

l
l
l
l
l
4.4

Maintenance, Cleaning

The devices do not require any maintenance, opening the devices invalidates warranty.
Cleaning :
S701...S724 (single channel STO) Instruction Manual
Transport by qualified personnel in the manufacturer's original recyclable packaging
Avoid shocks while transporting
Transport temperature:
Transport humidity:
If the packaging is damaged, check the unit for visible damage. In such an event, in-
form the shipper and the manufacturer.
Recyclable cardboard with inserts
Dimensions:
S701...S712 (HxWxD) 125x415x350 mm
S724
Labeling:
name plate on outside of box
Storage only in the manufacturer's original recyclable packaging
Max. stacking height:
Storage temperature:
Storage humidity:
Storage duration:
Less than 1 year: without restriction.
More than 1 year: capacitors must be re-formed before setting up and operating the
servo amplifier. To do this, remove all electrical connections and apply single-phase
230V AC for about 30 minutes to the terminals L1 / L2.
— if the casing is dirty: clean with Isopropanol or similar
NOTICE: Do not immerse or spray
— Dirt inside the unit: must be cleaned by the manufacturer
— For dirty protective grill on fan: clean with a dry brush
12/2010a
-25 to +70°C, max. rate of change 20K / hour,
class 2K3 acc. to EN61800-2
max. 95% relative humidity, no condensation,
class 2K3 acc. to EN61800-2
(HxWxD) 155x415x350 mm
8 cartons
-25 to +55°C, max. rate of change 20K / hour,
class 1K4 acc. to EN61800-2
5 ... 95% relative humidity, no condensation,
class 1K3 acc. to EN61800-2